Levelflex M FMP41C

Levelflex M FMP41C

  • Measuring principle: 

    Guided radar

  • Characteristic / Application

    Characteristic / Application

  • Interface measurement

    Clean interfaces liquid / liquid
    Simultaneous measurment of interface and overall level

  • Supply / Communication

    2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)

  • Accuracy

    Accuracy

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 200 °C
    (-40 °F … 392 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum … 40 bar
    (Vacuum … 580 psi)

  • Main wetted parts

    PTFE, PFA

  • Process connection

    DN40 … DN150

  • Process connection hygienic

    Tri-Clamp ISO2852
    DIN11851 DN50 PN40

  • Sensor length

    Rod: 4 m (178")
    Rope: 30 m (1181")

  • Application

    Application

  • Max. measurement distance

    Max. measurement distance

  • Communication

    4 … 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    FM
    CSA
    TIIS
    SIL
    WHG/ Overfill prevention
    EHEDG, 3A

  • Successor

    FMP52

  • Application limits

    High process temperatures (> 150 °C/302 °F)
    can favor diffusion of the process medium into
    the probe coating which may lead to a limited
    lifetime.:
    FMP45
    Interface measurement:
    Use coax system in favor (Bypass, stilling
    well)

Manufacturer

Model

FMP41C

מידות

קוטר:130 גובה:1200 רוחב:155